Safety measures for mine ventilation restoration, gas removal and power transmission

1. When the main ventilator is restarted due to power failure and other reasons, the method of air flow short circuit is adopted to discharge gas. When the gas concentration at the outlet of the main ventilator is not more than 2%, the damper is gradually closed

2. After the ventilation system is normal and the gas concentration at the outlet of the main ventilator does not exceed 0.75%, the ventilation and gas inspectors can enter the well to check the ventilation and gas conditions

3. When the gas concentration in the power supply place and distribution chamber of the underground full air pressure air supply falls below 0.5%, power can be transmitted to the underground, and other personnel can enter the well

4. If the local ventilator stops running for some reason, regardless of the length of the air stop time, the gas and carbon dioxide concentration in the air stop area must be checked before resuming ventilation. The inspection of gas by the tile inspector must be coordinated by the team leader or the safety officer; When entering the wind stop area, the two must walk from the outside to the inside and check one after the other. When the gas concentration reaches 3%, return to the original route

do not let go of the spring tension and compression testing machine during operation and application, especially during unloading. 5. The main ventilator or local ventilator in the mine stops running for some reason, resulting in gas accumulation. The following provisions shall be implemented for gas discharge:

⑴ when the maximum gas concentration in the air stop area is not more than 1% and the maximum carbon dioxide depth is not more than 1.5%, it can be directly discharged by the tile inspector, However, the tiles in the flow within 10m around the local ventilator and its switch also provide more choice space. The gas concentration shall not exceed 0.5%

⑵ when the gas concentration in the air stop area exceeds 1% or the carbon dioxide exceeds 1.5% and the maximum is not more than 3%, the tile inspector must ask the competent leader for instructions and designate a special person to cooperate to control the air flow and discharge gas

⑶ when the gas or carbon dioxide concentration in the wind stop area exceeds 3%, the tile inspector must report to the leader in charge. The mine shall formulate safety measures for gas discharge according to the actual situation on site, and assign professional personnel to discharge

6. Safety measures for gas discharge

⑴ when local gas accumulation with a volume of more than 0.5 cubic meters and a concentration of 2% occurs in the mining face and other roadways, the gas inspector shall deal with it immediately. The gas accumulation that cannot be handled immediately shall be reported to the leader in charge of the mine. The leader in charge shall put forward gas discharge measures and designate a special person to discharge. The operation must be stopped within 20m around, the personnel shall be evacuated and the power supply shall be cut off

⑵ when the roadway gas in the enclosed area is discharged, the mine shall put forward special safety measures for gas discharge. After being reviewed and approved by the technical director of the mine, the leader in charge of the mine shall command on the spot, and the mine rescue team shall assist in discharging the vanadium battery cost by 1019.27 yuan/kwh

⑶ when discharging gas, the gas concentration in the discharged air flow shall not exceed 2%; The gas depth after mixing the exhaust air flow with the full air pressure air flow shall not exceed 1.5%. Before gas discharge, the power supply must be cut off, the personnel must be evacuated and the warning must be set up in the area where the gas discharge flows

⑷ the principle of low concentration gas discharge shall be adhered to. The air must be returned after the advanced air, and the air duct shall be added section by section from the outside to the inside, or other means shall be used to control the gas concentration in the air flow